Gasfitting

Adept Gas Leak Detection and Repair

L B White offers expert guidance and solutions for domestic and commercial gas needs. Gas appliance installation, servicing, and safety checks, covering LPG and natural gas connections across Wellington Region.

Ensuring Safety and Efficiency by L B White

Gasfitting involves more than just the installation, alteration, or repair of gas pipes and appliances; it requires a licensed professional to guarantee safety and operational effectiveness. At L B White, we are gasfitting experts in the Wellington region, and we can provide authoritative advice and action on all gas matters. Remember, DIY gas works can lead to serious incidents and likely void any insurance policies you may have.

L B White Offers a Range of Gas Fitting Repairs and Services:

Adept Gas Leak Detection: Our certified gasfitters are adept at evaluating your gas system, making necessary repairs, and ensuring overall safety. We provide comprehensive services to ensure your gas systems comply with regulations and that all health and safety considerations are addressed effectively.

Expert Installation & Repairs for Gas Appliances: From gas hobs and cookers to water heaters and room heaters, our gasfitting services encompass installation, servicing, and repair for all your gas appliances. Be it the quick heat control of a gas hob, the precise temperature levels of a gas oven, the safe and economical operation of a gas fireplace, or the comforting warmth of a gas heater, we ensure optimal performance and safety of your appliances.

Proficient Gas Line Installations and Repairs: Our experienced gasfitting team handles the installation, repair, and maintenance of your gas lines professionally. If you smell gas or notice unusually high gas bills, this could be indicative of a gas leak, which requires urgent attention. L B White, the leading plumbers and gas fitters in Wellington, ensures that your gas lines are safe and operational.

Continuous Hot Water Systems: A continuous gas hot water system only heats water when needed, reducing your energy bills and your household's overall energy usage. These systems necessitate the skills of a licensed gas fitter for installation, and our proficient team is ready to get your system set up swiftly.

Reliable Gas Testing and Certification: The law requires testing and certification for all new gas installations or repairs. At L B White, we provide quick and reliable services for gas testing and certification, ensuring your gas systems meet safety standards and regulations.

DLM Wallace Lead Sheet / Acrylead

Product Description:

DLM Wallace Lead Sheet & Acrylead consist of virgin lead of at least 99.8% purity, machine cast in to sheet form of various dimension and thickness. Acrylead has a factory baked acrylic primer coating which inhibits the contact of water with the lead and its oxides, greatly reducing lead run-off which can cause staining on surrounding roof materials such as tiles. Lead Sheet & Acrylead are soft and malleable, making them a versatile flashing material. They offer strong resistance to corrosion and UV degradation, offering unparalleled longevity of service.

Scope of use:

Lead Sheet & Acrylead are used as a flexible weatherproof flashing to drain or deflect water back outside roof

and wall cladding systems. They are commonly used for flashing concrete, clay and slate tile roofs, for buildings described in Table 1 of NZS 3604:2011, and NASH Standard Part 2: May 2019- 1.3.1.

Relevant building code clauses

· B2 Durability – B2.3.1 (a)

· E2 External Moisture – E2.3.1. E2.3.2

· F2 Hazardous Building Materials – F2.3.1

Contribution to code compliance

B2 Durability – B2.3.1 (a)

When installed in accordance with DLM Wallace literature and NZBC E2/AS1, Lead Sheet & Acrylead will provide durability of no

less than 50 years. DLM Wallace manufactured Lead Sheet has an in-service history in New Zealand of over 100 years.

E2 External Moisture – E2.3.1. E2.3.2

When installed in accordance with DLM Wallace Literature and NZBC E2/AS1, Lead Sheet & Acrylead will contribute to satisfying

the these performance requirements on NZBC E2. DLM Wallace Lead Sheet & Acrylead (17kg/m2 grade and above) meet the requirements of NZBC E2/AS1 4.3.1. DLM Wallace Lead Sheet & Acrylead is manufactured in accordance with AS 1804:1976 (Soft Lead Sheet and Strip).

F2 Hazardous Building Materials – F2.3.1

Prior to working with DLM Wallace Lead Sheet & Acrylead, installers and handlers should familiarise themselves with the health and safety guidelines offered in the DLM Wallace Lead Sheet & Acrylead Material Safety Data Sheet.

Standards:

DLM Wallace Lead Sheet & Acrylead is manufactured in accordance with AS 1804:1976 (Soft Lead Sheet and Strip).

Composition:

DLM Wallace Lead Sheet & Acrylead consist of virgin lead of at least 99.8% purity, machine cast in to sheet form of various dimension and thickness. Acrylead has a factory baked acrylic primer applied to both sides of the sheet, which minimises run-off of lead oxides.

Limitations:


· Material compatibility must be considered when specifying and installing DLM Wallace Lead Sheet & Acrylead.


· Lead Sheet & Acrylead must not be used in contact with zinc-aluminium coated long-run steel or zinc- aluminium coated pressed metal tiles.


· Refer to NZBC E2 AS1, Table 21- Compatibility of materials on contact.


· Refer to NZBC E2 AS1, Table 22 – Compatibility of materials subject to run-off.


· Due to thermal expansion and contraction, individual pieces of Lead Sheet & Acrylead must not exceed the dimensions listed in the table below;

Weight (KG/M2)
Maximum Length (MM)
Maximum Girth (MM)
17
1300
600
20
1500
750
25
2000
800
30
2250
850

Maximum Size of Individual Pieces of Lead for All Flashing Applications

Installation Requirements:

Nominal Weight (KG/M2)
Nominal Thickness (MM)
Typical Uses
6
0.5
Sound proofing
12
1
Apron and cover flashings, hip and ridge
flashings, lead slates, chimney flashings and weatherings to cornices, parapets, full roof cladding, sound proofing, radiation shielding
Sound proofing, radiation shielding
17 (Plain sheet and Acrylead)
1.5
20
1.8
25
2.2
2.2
2.6
Parapet, box a tapered gutters, or situations that
demand extra length

Dlm Wallace Lead Sheet & Acrylead Grades
Flashings Must Be a Minimum of 17KG/M2

· Lap cover between individual sheets/pieces must be a minimum of 100mm

(Refer NZBC E2/AS1- 4.5.2 (f) )


· Parallel flashings must be dressed down in to the tile pan, and have a minimum cover of 150mm, with a minimum upstand of 100mm (75mm minimum upstand behind cladding). Refer NZBC E2/AS1- Figure 26.

· Transverse flashings must have a minimum cover of 150mm over the tile, and have a minimum upstand of 100mm (75mm minimum upstand behind cladding). Refer NZBC E2/AS1- Figure 26.


· Flashings should be designed so that while the lead is in position, free thermal movement is not restricted.

· Nails, screws and fixings should have a similar life expectancy, and thus should be copper, or stainless steel.


· When forming and shaping lead, caution must be taken to not over-stretch the lead, which can create thin areas with reduced integrity.

Maintenance Requirements:

To reduce the risk of run-off staining surrounding materials, a patination oil should be applied to un-painted lead sheet as soon as possible after fixing. Acrylead should be over painted with a quality acrylic external house paint and this coating should be maintained. As with all roofing material, Lead Sheet & Acrylead should be kept clean and free of moss, mould, lichen and

debris.

Warning and Bans:

DLM Wallace Lead Sheet & Acrylead is not subject to warning or ban under section 26 of the Building Act 2004.

Types of Products

Recommended Products

No items found.

Recommended Products

No items found.
No items found.

L B White Promise

When you're looking for top Wellington Plumbers, L B White is the company you can trust. We provide quality, reliable, and efficient plumbing maintenance services throughout the Wellington region. Our team of experienced professionals is dedicated to ensuring that your plumbing systems remain in top shape, saving you from future unexpected repair costs. Reach out to us today to schedule a maintenance consultation or to learn more about our services.

Send a Message

Thank you! Your submission has been received!
Oops! Something went wrong while submitting the form.

Get in Contact

office@lbwhite.co.nz
04 587 1023
Mon to Fri 8:00AM - 4:30PM
42 Victoria Street, Alicetown, Lower Hutt